Honalink

Welcome to our online store!
Availability: In Stock

40G QSFP+ to Four 10G SFP+ Copper Direct Attach Breakout Cable

SKU: OPT-40G -2424

$120.00 – $179.00


Description

The QSFP-4SFP-AOCxM is a Four-Channel, Pluggable, Parallel, Fiber-Optic QSFP+ Active Optical Cable (AOC) to 4× SFP+ Active Optical Cable break-out solution. This Breakout cable is intended for 40G to 4× 10G applications.

This AOC is a high performance cable for short-range multi-lane data communication and interconnect applications. It integrates four data lanes in each direction with 40 Gbps aggregate bandwidth. Each lane can operate at 10.3125 Gbps. These cables also support 4 x 10G InfiniBand QDR applications and are backwards compatible to the 4 × 5G IB DDR and 4 × 2.5G IB single IB SDR applications.

This product is leveraged from REALSEA QSFP+ to QSFP+ Active Optical Cable productand SFP+ Active Optical Cable product. Where applicable, consult these respective datasheets

This AOC incorporates REALSEA’ proven integrated circuit and VCSEL technology to provide reliable long life, high performance, and consistent service.

Product Features

  • Compliant to the 40GBASE-SR4 and XLPPI
  • Specification per IEEE 802.3ba-2010 and supporting
  • 40G-IB-QDR / 20G-IB-DDR / 10G-IB-SDR applications
  • Compliant to the industry standard SFF-8436
  • Power Level 1: Max Power < 1.5 W
  • Operate at 10.3125 Gbps per channel with 64b/66b encoded data for 40GbE application and at 10 Gbps with 8b/10b compatible encoded data for 40G-IB-QDR application
  • Compliant to the electrical specifications per SFF-8431 Specifications forEnhanced Small Form Factor Pluggable Module
  • Mechanical specifications per SFF Committee SFF-8432 Improved Pluggable Form factor “IPF”
  • Maximum power dissipation 35W per end.
  • 0 to 70Cdegree case temperature operating range
  • Proven High Reliability 850 nm technology: VCSEL transmitter and PIN receiver
  • Hot pluggable for ease of servicing and installation
  • Two Wire Serialinterface
  • Utilizes optical fiber for high density and thin, lightweight cablemanagement

Applications

  • 40GbE and 10GbE break-out applications for Datacom switch and router connections
  • 40G to 4×10G density applications for Datacom and Proprietary protocol applications
  • Data center

Absolute Maximum Ratings

The operation in excess of any absolute maximum ratings might cause permanent damage to this module.

ParameterSymbolMinMaxUnitNote
Storage TemperatureTST-4085degC
Relative Humidity(non-condensing)RH085%
Operating Case TemperatureTOPC070degC
Supply VoltageVCC-0.33.6V
Input VoltageVin-0.3Vcc+0.3V

 

ParameterSymbolMinTypicalMaxUnit
Operating Case TemperatureTOPC070degC
Power Supply VoltageVCC3.133.33.47V
Data RateDR10.311.3Gbps
Data Speed Tolerance∆DR-100+100ppm
Link Distance with OM3 fiberD0100m
Control* Input Voltage HighVih2VCC+0.3V
Control* Input Voltage LowVil-0.30.8V
I2C Serial Interface frequencefs400kHz
Power Supply Noise50mVpp
Receiver Differential Data Output Load100mVpp

 

Active Cable-End Electrical Characteristics

The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted. Typical values are for Tc = 40 °C, Vcc = 3.3 V

ParameterSymbolMinTypicalMaxUnit
QSFP+ 40G Active Cable-End Power Consumption1.5W
QSFP+ 40G Active Cable-End Power Supply Current300mA
SFP+ 10G Active Cable-End Power Consumption0.35W
SFP+ 10G Active Cable-End Power Supply Current100mA

QSFP+AOC-end Electrical Characteristics

ParameterSymbolMinTypicalMaxUnit
Differential input impedanceZin90100110ohm
Differential Output impedanceZout90100110ohm
Differential input voltage amplitudeΔVin3001100mVp-p
Differential output voltage amplitudeΔVout400800mVp-p
Bit Error RateBRE-12
Input Logic Level HighVIH2.0VCCV
Input Logic Level LowVIL00.8V
Output Logic Level HighVOHVCC-0.5VCCV
Output Logic Level LowVOL00.4V

 

QSFP+ AOC-end Pin Descriptions

PINLogicSymbolName/DescriptionNote
1GNDGround1
2CML-ITx2nTransmitter Inverted Data Input
3CML-ITx2pTransmitter Non-Inverted Data output
4GNDGround1
5CML-ITx4nTransmitter Inverted Data Input
6CML-ITx4pTransmitter Non-Inverted Data output
7GNDGround1
8LVTLL-IModSelLModule Select
9LVTLL-IResetLModule Reset
10VccRx﹢3.3V Power Supply Receiver2
11LVCMOS-I/OSCL2-Wire Serial Interface Clock
12LVCMOS-I/OSDA2-Wire Serial Interface Data
13GNDGround
14CML-ORx3pReceiver Non-Inverted Data Output
15CML-ORx3nReceiver Inverted Data Output
16GNDGround1
17CML-ORx1pReceiver Non-Inverted Data Output
18CML-ORx1nReceiver Inverted Data Output
19GNDGround1
20GNDGround1
21CML-ORx2nReceiver Inverted Data Output
22CML-ORx2pReceiver Non-Inverted Data Output
23GNDGround1
24CML-ORx4nReceiver Inverted Data Output1
25CML-ORx4pReceiver Non-Inverted Data Output
26GNDGround1
27LVTTL-OModPrsLModule Present
28LVTTL-OIntLInterrupt
29VccTx+3.3 V Power Supply transmitter2
30Vcc1+3.3 V Power Supply2
31LVTTL-ILPModeLow Power Mode
32GNDGround1
33CML-ITx3pTransmitter Non-Inverted Data Input
34CML-ITx3nTransmitter Inverted Data Output
35GNDGround1
36CML-ITx1pTransmitter Non-Inverted Data Input
37CML-ITx1nTransmitter Inverted Data Output
38GNDGround1

 Notes:

  1. Module circuit ground is isolated from module chassis ground within the module. GND is the symbol for signal and supply (power) common for QSFP modules.
  2. The connector pins are each rated for a maximum current of 500mA.

未标题 22 4

ModSelL Pin

The ModSelL is an input pin. When held low by the host, the module responds to 2-wire serial communication commands. The ModSelL allows the use of multiple QSFP modules on a single 2-wire interface bus. When the ModSelL is “High”, the module will not respond to any 2-wire interface communication from the host. ModSelL has an internal pull-up in the module.

ResetL Pin

Reset. LPMode_Reset has an internal pull-up in the module. A low level on the ResetL pin for longer than the minimum pulse length (t_Reset_init) initiates a complete module reset, returning all user module settings to their default state. Module Reset Assert Time (t_init) starts on the rising edge after the low level on the ResetL pin is released. During the execution of a reset (t_init) the host shall disregard all status bits until the module indicates a completion of the reset interrupt. The module indicates this by posting an IntL signal with the Data_Not_Ready bit negated. Note that on power up (including hot insertion) the module will post this completion of reset interrupt without requiring a reset.

LPMode Pin

REALSEA QSFP+ SR4 operate in the low power mode (less than 1.5 W power consumption) This pin active high will decrease power consumption to less than 1W.

ModPrsL Pin

ModPrsL is pulled up to Vcc on the host board and grounded in the module. The ModPrsL is asserted “Low” when the module is inserted and deasserted “High” when the module is physically absent from the host connector.

IntL Pin

IntL is an output pin. When “Low”, it indicates a possible module operational fault or a status critical to the host system. The host identifies the source of the interrupt by using the 2-wire serial interface. The IntL pin is an open collector output and must be pulled up to Vcc on the host board.

SFP+ AOC-end Electrical Specifications

ParameterSymbolMinTypicalMaxUnit
Differential input impedanceZin90100110ohm
Differential Output impedanceZout90100110ohm
Differential input voltage amplitude AmplitudeΔVin1001800mVp-p
Differential output voltage amplitudeΔVout400800mVp-p
Bit Error RateBRE-12
Input Logic Level HighVIH2.0VCCV
Input Logic Level LowVIL00.8V

SFP+ AOC-end Pin Descriptions

PINSymbolName/DescriptionNote
1VeeTTransmitter Signal GroundNote 1
2TX_FAULTTransmitter Fault (LVTTL-O) – Not used. Grounded inside the moduleNote 2
3TX_DISABLETransmitter Disable (LVTTL-I) – High or open disables the transmitterNote 3
4SDATwo Wire Serial Interface Data Line (LVCMOS – I/O)

(same as MOD-DEF2 in INF-8074)

Note 4
5SCLTwo Wire Serial Interface Clock Line (LVCMOS – I/O)

(same as MOD-DEF1 in INF-8074)

Note 4
6MOD_ABSModule Absent (Output), connected to VeeT or VeeR in the moduleNote 5
7RS0Rate Select 0 – Not used, Presents high inputimpedance.
8RX_LOSReceiver Loss of Signal (LVTTL-O)Note 2
9RS1Rate Select 1 – Not used, Presents high input impedance.
10VeeRReceiver Signal GroundNote 1
11VeeRReceiver Signal GroundNote 1
12RD-Receiver Data Out Inverted (CML-O)
13RD+Receiver Data Out (CML-O)
14VeeRReceiver Signal Ground
15VccRReceiver Power + 3.3 V
16VccTTransmitter Power + 3.3 V
17VeeTTransmitter Signal GroundNote 1
18TD+Transmitter Data In (CML-I)
19TD-Transmitter Data In Inverted (CML-I)
20VeeTTransmitter Signal GroundNote 1

 

Notes:

  1. Module circuit ground is isolated from module chassis ground within the module. GND is the symbol for signal and supply (power) common for SFP modules.
  2. This is an open collector/drain output that on the host board requires a 4.7 kΩ to 10 kΩ pullup resistor to VccHost. See the figure below..
  3. This input is internally biased high with a 4.7 kΩ to 10 kΩ pullup resistor to VccT.
  4. Two-Wire Serial interface clock and data lines require an external pullup resistor dependent on the capacitance load.
  5. This is a ground return that on the host board requires a 4.7 kΩ to 10 kΩ pullup resistor to VccHost.

未标题 24 4

QSFP+ AOC-end Power Supply Filtering

未标题 25 4

Optical Fiber Specifications

ParameterSpecification
Tight buffer colorBlue
Tight buffer materialPVC
Fiber type62.5/125 (OFS)

Bandwith:160 MHz.km @ 850 nm

Jacket materialPVC
Cable diameter mm3.0 ± 0.1
Cable weight Kg/km7.0
Min. bending radius mm30
Attenuation dB/km≤ 3.5 at 850 nm

≤ 1.5 at 1300 nm

Short tension N120
Operation temperature °C-20~70

 

SFP+ AOC endMechanical Specifications

未标题 26 4

未标题 27 4

QSFP+ AOC end Mechanical Specifications

未标题 28 4

Ordering Information

Part NumberProduct Description
HNQSFP-4SFP-AOC1M40G QSFP+ to 4x SFP+Active Optical Cable, 1m (3ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC2M40G QSFP+ to 4x SFP+Active Optical Cable, 2m (7ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC3M40G QSFP+ to 4x SFP+Active Optical Cable, 3m (10ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC5M40G QSFP+ to 4x SFP+Active Optical Cable, 5m (16ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC7M40G QSFP+ to 4x SFP+Active Optical Cable, 7m (23ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC10M40G QSFP+ to 4x SFP+Active Optical Cable, 10m (33ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC15M40G QSFP+ to 4x SFP+Active Optical Cable, 15m (49ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC20M40G QSFP+ to 4x SFP+Active Optical Cable, 20m (66ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC25M40G QSFP+ to 4x SFP+Active Optical Cable, 25m (82ft),            0ºC ~ +70ºC
HNQSFP-4SFP-AOC30M40G QSFP+ to 4x SFP+Active Optical Cable, 30m (98ft),            0ºC ~ +70ºC

Reviews

There are no reviews yet.

Be the first to review “40G QSFP+ to Four 10G SFP+ Copper Direct Attach Breakout Cable”

Your email address will not be published. Required fields are marked *

You're viewing: 40G QSFP+ to Four 10G SFP+ Copper Direct Attach Breakout Cable $120.00 – $179.00
Select options
Shopping cart close